Fuel Meters Series VZF 15/50

Downloads

AttachmentSize
Brochure1.77 MB
Technical documentation1.64 MB

Description of fuel meters:

New, the most up to date series of fuel meters, equipped with an electronic multifunctional counting device with an integrated analogue and pulse output. They are designed for long-term operation with fuel of any quality, the accuracy of measurement does not depend on viscosity (i.e. they are designed for a wide range of viscosity).

 

General specifications:
– the display indicates total consumption, current consumption (measurement units - m3 , liters, gallons USA);
– easy parameter settings with the help of menu;
– meters with threaded and flange connections;
– designed for horizonal, vertical or diagonal mounting.

 

Technical specifications:

 
  Тype   VZF15 VZF20 VZF25 VZF40 VZF50  
  Nominal diameter   mm 15 20 25 40 50  
  inch ½ ¾ 1 1 ½ 2  
  Mounting length   mm 165 165 190 300 350  
  Nominal pressure with thread   bar 16  
  with flange   bar 25  
  Max. Теmperature Tmax °С 130,180  
  Маx. consumption Qmax l/h 600 1500 3000 9000 30000  
  Continuous consumption Qn l/h 400 1000 2000 6000 20000  
  Мin. consumption Qmin l/h 10 30 75 225 750  
  Max. error     ±1% from actual value  
  Repeatability     ±0,2%  
  Filter mesh size   mm 0,400 0,400 0,400 0,800 0,800  
  Strainer mesh size max. mm 0,250 0,400 0,400 0,600 0,600  
  Volume of the measuring chamber   сm3 12 36 100 330 1200  
  Body cover     lacquered paint, RAL 3013  
  Weight with screws   ≈kg 2,2 2,5 4,2 17,3 -  
  Weight with flange PN 25   ≈kg 3,8 4,5 7,5 20,3 41  
 

Мin. quantity:

Total consumption meter

Meter with resettable values

Indication of actual consumption

 

 

 

l

l

l/h

 

 

without a decimal point

1 decimal digit

1 decimal digit

 
  Registration capacity   l 100 000 000  
  Duration of regastration at Qn without overflow   hour 128 000 100 000 50 000 16 667 5000  
 

Outputs:

Pulses for totalizer

 

quantity/pulse

 

Pulse value and width can be parametrized

 
  Current 4...20 mА for consumption I4/Q1,I20/Q2 Consumption for 4 and 20 mА can be parametrized  
  Frequency for consumption f1/Q1,f2/Q2 Consumption frequency and value can be parametrized  
  Switch for limiting values QminQmax Min., max. and hysteresis can be parametrized